Bis-2-ethylhexyl-phthalate, also known as Di (2-ethylhexyl) phthalate or DEHP, is one of the man-made chemicals called phthalates or phthalic acid esters that is added to plastics to make them more flexible. This chemical is a plasticizer in polyvinylchloride (PVC), rubber, and styrene, and is commonly used in beverage and food packaging. The chemical is colorless and virtually odorless and is a semi-volatile organic compound. DEHP can be found in a variety of commercial products including medical tubing, garden hoses, material used for beverages and food, vinyl chloride resins, and plumbing materials/piping (PVC). "It is also used in cosmetic and insect repellents, in liquid soaps and detergents, as "carriers" for pesticides, in lacquers, lubricating oils, photographic film, wire casings and during the manufacture of paper." (Source)
DEHP has been associated with gastrointestinal disorders and has been classified as a probable human carcinogen. From animal studies, the available data indicate that oral exposure is associated with development and reproductive issues and adverse effects on the kidneys and liver. (Source) DEHP can enter the body through skin contact and inhalation, but a more common route for consumers is via consumption. After consumption, the chemical enters the bloodstream via the intestines and lungs. In the body it is then converted to monoethylhexyl phthalic acid (MEHP) and 2-ethylhexanol. MEHP, which has been shown to have a cardio toxic effect, may affect the testes, adversely impacts fetal development, and appears to be transferred from mother to child during breastfeeding, as well as being a possible endocrine disruptor in humans (Source). In animal studies, 2-ethylhexanol was associated with adverse effects on the blood, kidneys, liver, and spleen and skin contact is associated with localized redness (Source).
The Department of Health and Human Services (DHHS) has determined that DEHP may reasonably be assumed to be a human carcinogen. The EPA has determined that DEHP is a probable human carcinogen (Source). Ingestion of DEPH may cause irritation of the stomach and diarrhea. In addition, it may act as an endocrine disruptor and may bioaccumulate.
DEHP is regulated as a primary drinking water standard: the MCL is 0.006 mg/L, and the MCLG is 0 or zero. The DWEL is 0.7 mg/L and if the concentration is 0.3 mg/L or higher then there is a significant risk of the cancer. The Cancer Risk is based on the concentration of a chemical in drinking water corresponding to an excess estimated lifetime cancer risk of 1 in 10,000. The EPA considers there is enough evidence to show that DEHP is carcinogenic in animals but does not have enough information to definitively say the same of humans, concluding that it probably is carcinogenic in humans. California has a drinking water standard of 0.004 mg/L for DEHP.
The EPA estimates that, if an individual were to continuously ingest water containing DEHP at an average of 3 μg/L(0.003 mg/L) over his or her entire lifetime, that person would theoretically have no more than a one-in-a-million increased chance of developing cancer as a direct result of ingesting water containing this chemical." (Source)
On an annual basis over 2 million tons of DEHP are produced throughout the world. This chemical does not have a noticeable color or odor. Excluding inhalation and exposure through food packaging, this contamination is typically associated with the use of materials that are not NSF-certified for potable water piping (see NSF International Standard 61), water containers not designed for potable water, and contamination related to the manufacturing of the chemical compound or disposal of the associated waste materials. Note: If you are using PVC piping in your home, we recommend you use piping that is marked as NSF-pw/NSF61. NSF-dwv should only be used for drain piping, waste, and vent applications.
One study states: "DEHP was found in drinking water, at levels ranging from 0.04 to 30 parts per billion (ppb)." (Source)
"Investigators have attributed these concentrations to issues related to the water well construction, degradation (corrosion or aging) of the well casing, microbial action corrosion (iron bacteria), sample tubing and abrasion on well casing, and the bailer and rope associated with bailing procedures." (Source)
Level 1 Testing is done with simple observations that an individual can make with their own senses such as sight, smell, and taste. These observations can be readily apparent or can be observed as they change over time. In addition, accessible related information about the home can also be used to narrow down the cause of your water issues.
What are the options for self-testing or screening, our best answer is awareness. What is the piping in your home? If you are on "city water", what does your Annual Consumer Confidence Report say? Are you located near a landfill or manufacturer that produces or uses this compound? Are you located in an agricultural area or an area with high pesticide / herbicide/ insecticide application?
Other than a water test, the only other way to check your exposure to this chemical would be to have your blood or urine tested.
Observations that may suggest you could have an issue with DEHP:
Level 2 Testing is Do-It-Yourself testing that can be done in your own home using a Testing Kit. After you’ve done Level 1 Testing, Level 2 Testing can confirm if your observations are correct. If your test results reveal the presence of a contaminant that is cause for concern, you can either proceed to determine the best treatment (see below) or continue to Level 3 Testing.
We are not aware of a low-cost screening test to check your water or air for Bis (2-Ethylhexyl)phthalate, but you should check the consumer products you use to see if they contain phthalates (Source) and you may want to use phthalate-free consumer products, such as toys, water bottles, and food wrapping/containers.
<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POE Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POE Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device)</div>
<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POE Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POE Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device)</div>
Level 3 Testing is done through an accredited Water Testing Laboratory. With Level 3 Testing, you can order a testing kit that is used to prepare your sample and submit it to the lab. By utilizing a lab, you have the assurance that a certified water expert had analyzed your water sample. If your test results reveal the presence of a contaminant that is cause for concern, you can either proceed to determine the best treatment options (see below) or continue to Level 4 Testing - Certified Testing.
Not all informational water quality tests include Di (2-ethylhexyl) phthalate and other phthalates. The following are informational water quality tests that include testing for this and similar compounds. We would recommend the Tap Score Advanced Well Water kit for both well water and city water.
<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POE Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POE Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device)</div>
A Level 4 Certified Test Test uses chain-of-custody with a water professional coming to your home to prepare the water sample and then works with an accredited laboratory in order to certify your test results. This type of testing not only gives you the highest level of assurance in the accuracy of your test results, but can also be used as a document in legal cases. For Baseline Testing, we recommend that you use Certified Testing.
If you need certified testing for Bis (2-ethylhexyl)phthalate, we would advise you test for a broader range of herbicides and pesticides, other phthalates, and bisphenol, plus contaminants that are more likely associated with the source of the contamination. If you do not know the source of the contamination and nature of the contaminant, we strongly recommend conducting informational water testing first to characterize the general water quality and test for a broad range of chemical compounds. If you need help with developing a screening program or finding a certified laboratory, please contact our team.
It is unlikely that there will be significant problems with phthalates in a public water supply system, but it is more likely this problem would be associated with a transient non-community water system or a private system or a water source that is directly downgradient from an industrial user, wastewater treatment plant, landfill, or a drinking water system using PVC piping that is not NSF Standard 61.
For the short-term and assuming the concentrations are relatively low, we recommend making sure to flush the line prior to use and considering the installation of some point-of-use granular-activated-carbon filtration system.
<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POE Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POE Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device)</div>
For the long-term, it will be necessary to characterize the water source chemically and biologically. Understand the source or sources, determine if the distribution system is contributing to the problem, and determine if there are any other contaminants that were not initially identified or that may interfere with the use of a granular-activated-carbon filtration system. The best way to develop a long-term solution is to have a comprehensive water quality test and work with a water quality professional.
<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>
<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POE Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POE Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device)</div>
If the concentration is at or over 0.006 mg/L - Recommendation: Seek Advice from a Local Professional (Customized Solution) Contact Us