Indoor
Outdoor
+
Outdoor
Indoor
This is a newly redesigned Water-Research.net page
Page Archive

Get Informed | Trichloroethylene

What is Trichloroethylene?

Trichloroethylene (TCE) is a solvent that is used as a degreasing agent for metal parts used in consumer products like glues, dry cleaning agents, finishes, paint/stain removers, typewriter correction fluid, lubricants, adhesives, used to make other chemicals like refrigerants. TCE is clear and colorless, sometimes with a blue tint, and has a sweet, fruity odor like chloroform or ether; it is highly volatile. Trichloroethylene is also known as TCE, acetylene trichloride, ethylene trichloride, and trichloroethene. Primary issues with TCE contamination are typically associated with old dumps and landfills and historic industrial spills and releases.

How Does Trichloroethylene Become a problem?

Exposure to TCE has been associated with adverse impacts on the central nervous system, fetal development, immune system, reproductive system, kidneys, and the liver. TCE is also associated with an increased risk of liver cancer.

The likelihood of a health effect depends on the amount and duration of TCE exposure.

What are the Health Risks for Trichloroethylene?

From animal studies, TCE has been associated with poor or slower rate of development, such as low body weight, adverse impacts to the nervous and immune systems, and heart defects. Long-term exposure has been associated with cancer (liver cancer very likely and blood cancer strongly suggested). Exposure to TCE can happen through consumption, dermal contact, and inhalation. Inhalation is one reason vapor exposure is a concern for TCE. In some animal studies, exposure to trichloroethylene during development may have caused effects such as decreased body weight, increased incidences of heart defects, functional or structural changes in the developing nervous system, and effects on the immune system." (Source)

Some human studies indicate that trichloroethylene may cause developmental effects such as spontaneous abortion, congenital heart defects, central nervous system defects, and small birth weight. However, these people were exposed to other chemicals as well.

What are the Standards for Trichloroethylene?

Trichloroethylene is regulated as a primary drinking water standard and the MCL is 0.005 mg/L, but the maximum contaminant level goal is actually zero.  Maine has a drinking water limit of 0.004 mg/L and Minnesota has a chronic health risk limit of 0.0004 mg/L and a cancer-based limit of 0.002 mg/L. The standard was set because of concerns related to inducing cancer in humans. The EPA has a DWEL of 0.2 mg/L (noncarcinogenic) and long-term exposure of 0.3 mg/L because of the risk of cancer.

Get Tested | Trichloroethylene

You should get your drinking water tested for TCE when you suspect your drinking water has been impacted by an old chemical disposal system, chemical manufacturer, landfill, or an industrial spill or release. In addition, TCE can have a sweet or chloroform odor at 28 mg/l, but this occurs when the concentration is over 1000 times the drinking water standard.

Level 1 | Observational Self-Testing

Notes on Level 1 Testing for Trichloroethylene

There are few warning signs of a problem with trichloroethylene when the concentration at which TCE produces an odor is so much higher than the drinking water standard. The best screening test is location, location, and location. Are you located in an area that has historic problems associated with the use of TCE?  If you are on a city water system, it is not likely that trichloroethylene would exceed the drinking water limit, but it has been detected in over 450 public water systems.

Try Our Level 1 Drinking Water Self-Diagnostic Tool
Have water issues? Answer our self-diagnosis questionnaire from your observations to get an initial diagnosis. Then follow our recommended steps to remediate your issue.
Self-Diagnostic Tool

Level 2 | Do-It-Yourself Water Testing

Level 2 Testing is Do-It-Yourself testing that can be done in your own home using a Testing Kit. After you’ve done Level 1 Testing, Level 2 Testing can confirm if your observations are correct. If your test results reveal the presence of a contaminant that is cause for concern, you can either proceed to determine the best treatment (see below) or continue to Level 3 Testing.

Notes on Level 2 Testing for Trichloroethylene

We are not aware of a low-cost screening test or meter that can be used to document the level of TCE in your water. In cases of TCE exposure via an industrial spill an airborne route of exposure is also a possible route of contamination. There are some reliable low-cost air quality monitors that can monitor for total natural & synthetic volatile organic compounds causing most odors (TVOC). TCE breaks down within the body and is temporarily stored in fat and released into the urine.  If you are using a private water source, we would recommend you order a Neighborhood Environmental Report.

Recommended Level 2 Tests
Water Check Deluxe

<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>

CityCheck Standard

<div class="product-note in-L4-sulfur-treatment">Note: Use in combination with Sulfate-Reducing Bacteria Test</div>

ST-FILT-B-01
Filter Water
Brondell Cypress Countertop Water Filtration System (Code A27AC)

<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>

ST-CRYS-T-02
Crystal Quest
Triple Under-Sink Water Filter, 8-Stage

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-G-01
Crystal Quest
GAC Carbon Commercial Water Filter System

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>

LT-CRYS-E-02
Crystal Quest
Eagle 4000A Whole House Filter and Water Conditioner

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POE Device)</div>

LT-CRYS-T-02
Crystal Quest
Thunder 2000M Reverse Osmosis System with Ultrafiltration

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

Recommended Products
National Testing LabsL3-NATE-W-2 | WaterCheck Deluxe

<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>

View
National Testing LabsL3-NATE-C-3 | CityCheck Standard

<div class="product-note in-L4-sulfur-treatment">Note: Use in combination with Sulfate-Reducing Bacteria Test</div>

View
Filter WaterST-FILT-B-01 | Brondell Cypress Countertop Water Filtration System

<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>

View
Crystal QuestST-CRYS-T-02 | Triple Under-Sink Water Filter, 8-Stage

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

View
Crystal QuestLT-CRYS-G-01 | GAC Carbon Commercial Water Filter System

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>

View
Crystal QuestLT-CRYS-E-02 | Eagle 4000A Whole-House Filter and Water Conditioner

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POE Device)</div>

View
Crystal QuestLT-CRYS-T-02 | Thunder 2000M Reverse Osmosis System with Ultrafiltration

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

View
Neighborhood Environmental Report

Order a Neighborhood Environmental Report to learn about potential hazards in your community.

Level 3 | Informational Water Testing

Level 3 Testing is done through an accredited Water Testing Laboratory. With Level 3 Testing, you can order a testing kit that is used to prepare your sample and submit it to the lab. By utilizing a lab, you have the assurance that a certified water expert had analyzed your water sample. If your test results reveal the presence of a contaminant that is cause for concern, you can either proceed to determine the best treatment options (see below) or continue to Level 4 Testing - Certified Testing.

Notes on Level 3 Testing for Trichloroethylene

Most quality informational water testing kits include testing for trichloroethylene and other volatile organic compounds.  Because trichloroethylene may impact the immune system, we recommend conducting the 5 Stands Testing related to environmental exposure. For City Water customers, it is unlikely that trichloroethylene is present in your water in a concentration over the drinking water standard, but it may be present. For City Water users, we recommend the National Testing Labs City Water Check Standard. For private water systems and well water in semi-rural and rural areas we recommend the Water Check Deluxe. If you are only interested in the VOC testing and have already conducted a comprehensive testing for metals and other contaminants, we recommend the Tap Score VOC testing kit.

Recommended Level 3 Tests
Water Check Deluxe

<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>

CityCheck Standard

<div class="product-note in-L4-sulfur-treatment">Note: Use in combination with Sulfate-Reducing Bacteria Test</div>

ST-FILT-B-01
Filter Water
Brondell Cypress Countertop Water Filtration System (Code A27AC)

<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>

ST-CRYS-T-02
Crystal Quest
Triple Under-Sink Water Filter, 8-Stage

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-G-01
Crystal Quest
GAC Carbon Commercial Water Filter System

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>

LT-CRYS-E-02
Crystal Quest
Eagle 4000A Whole House Filter and Water Conditioner

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POE Device)</div>

LT-CRYS-T-02
Crystal Quest
Thunder 2000M Reverse Osmosis System with Ultrafiltration

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

Level 4 | Certified Water Testing

A Level 4 Certified Test Test uses chain-of-custody with a water professional coming to your home to prepare the water sample and then works with an accredited laboratory in order to certify your test results. This type of testing not only gives you the highest level of assurance in the accuracy of your test results, but can also be used as a document in legal cases. For Baseline Testing, we recommend that you use Certified Testing.

Notes on Level 4 Testing for Trichloroethylene

If you need certified testing for trichloroethylene, it would be advisable to test for a broader range of volatile organic compounds, metals, and bacterial quality.

Neighborhood Environmental Report

Order a Neighborhood Environmental Report to learn about potential hazards in your community.

Get Treatment | Trichloroethylene

It is unlikely that a city or regulated community water supply sources would be contaminated with TCE, but this is more likely for private water supply systems or transient non-community systems. This may be a concern if you are located near a leaky industrial site, contaminated site, old landfill, an area with a known or suspected release, or in an area with a historic use of TCE. Volatile organic compounds can typically be treated and removed from water using a combination of air sparging/ air stripping, Carbon Filtration, and Reverse Osmosis, but reverse osmosis is used as only a final barrier.

Short Term Treatment

Because of concerns related to the exposure to TCE via consumption, inhalation, and dermal contact, the primary recommendation is to develop an alternative potable water source and to use bottled water. For trace levels of TCE and volatile organic contamination, it may be advisable to use a point-of-use Carbon Filtration.

Recommended Short-Term Water Treatments

<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>

<div class="product-note in-L4-sulfur-treatment">Note: Use in combination with Sulfate-Reducing Bacteria Test</div>

ST-FILT-B-01
Filter Water

<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>

ST-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-G-01
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>

LT-CRYS-E-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POE Device)</div>

LT-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

If concentration is at or over 0.004 mg/L -Submit a Request for Consultation with the KnowYourH20 Team. Contact Us

Long Term Treatment

Regarding developing a long-term solution, it is not only critical to understand the source, extent, and nature of the contamination, but also to understand the secondary contaminants that may be associated with TCE. For example, TCE contamination associated with old landfills will typically also have elevated levels of trace metals, Iron, Manganese, heterotrophic bacteria, some salts, and other organics. Therefore, the treatment system may need to include oxidation/filtration, air stripping or Carbon Filtration, UV Disinfection, and even Reverse Osmosis. In addition, it is also advisable to remediate or mitigate the contamination event or release before implementing a long-term solution.

Recommended Long-Term Water Treatments

<div class="product-note in-L4-carbon-filtration">Note: For rural Areas with <a href="/indoor-6/herbicides-pesticides">Herbicides and Pesticides</a> Usage</div>

<div class="product-note in-L4-sulfur-treatment">Note: Use in combination with Sulfate-Reducing Bacteria Test</div>

ST-FILT-B-01
Filter Water

<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>

ST-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-G-01
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POE Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POE Device System Component</div>
<div class="product-note in-L6-bromate">Note: If the concentration is < 0.01 mg/L (POE Device System Component)</div>
<div class="product-note in-L4-methyl-tertiary">Note: Concentrations < 40 ppb</div>

LT-CRYS-E-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POE Device)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POE Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POE Device)</div>

LT-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

If the concentration is at or over 0.004 mg/L - Recommendation: Seek Advice from a Local Professional (Customized Solution). Contact Us

Archive Page Reference
This is a newly redesigned Water-Research.net page. To reference related archived Water-Research.net page(s) click the link(s) below:
No items found.

in-L6-trichloroethylene